¡ß System
Configuration
|
|
¡á
PLC System : SIEMENS S5-135/155U
,CPU928B(948) ¡á
Extension Units : IM304 &
IM308B to ET200U ¡á
Network : PROFIBUS-DP ¡á
Communication Processor : CP1430
TF ¡á HMI Visualization
: SIEMENS WinCC ¡á
Control Units -.
Heater control : IP244 -.
Drive Control : SIEMENS Micro
Master -.
RF-Power Control -.
DC-Power Control -.
Gas flow control : Ar &
Ar+O2
|
|
¡á
Serial
Networking
|
|
|
|
|
[ CP544-4
Presetting ]
|
[ CP544-2
Presetting ]
|
|
|
How
to use for CP544
|
|
¡á
Communication Processor : CP544
-.
Åë½Å¸ðµâ·Î´Â SIEMENSÀÇ CP544
¸ðµâÀ» »ç¿ëÇÏ¿© 2´ëÀÇ Central
Units°ú PC°£ÀÇ Åë½ÅÀ» ÇÒ ¼ö
ÀÖµµ·Ï Çß½À´Ï´Ù.
CP544 Åë½Å¸ðµâ¿¡´Â Duel Interface
Module(752 Module)À» »ç¿ëÇÏ¿©
1°³´Â Central
Units°£ÀÇ »óÈ£ Data Àü¼ÛÀ» ´ã´çÇÏ°í
³ª¸ÓÁö 1°³´Â °¢ Central Unit°ú
PCÀÇ COM Port·Î °¢°¢ ¿¬°áµÇ¾î
ÀåºñÀÇ ÀÛ¾÷ ÇöȲÀ» ½Ç½Ã°£À¸·Î
¸ð´ÏÅ͸µÇÒ ¼ö ÀÖµµ·Ï ¼³°èÇÏ¿´½À´Ï´Ù.
|
|
CP
Programming in CPU
|
|
¡á
SEND / RECEIVE Program -.
CPU Program of Central Unit
1 CP544-1ÀÇ
1¹ø 752 ModuleÀº Central Unit
2ÀÇ CPU¿Í Åë½ÅÇÒ ¼ö ÀÖµµ·Ï SEND
(CPU2°¡ SEND ÀÛ¾÷ÀÏ °æ¿ì RECEIVE)
ÀÛ¾÷À» ÇÒ ¼ö ÀÖµµ·Ï ÁöÁ¤ÇÕ´Ï´Ù. -.
CPU Program of Central Unit
2 CP544-2ÀÇ
1¹ø 752 ModuleÀº Central Unit
1ÀÇ CPU¿Í Åë½ÅÇÒ ¼ö ÀÖµµ·Ï RECEIVE
(CPU1ÀÌ RECEIVE ÀÛ¾÷ÀÏ °æ¿ì
SEND) ÀÛ¾÷À» ÇÒ ¼ö ÀÖµµ·Ï ÁöÁ¤ÇÕ´Ï´Ù. ¡á
SEND ALL / RECEIVE ALL Program -.
CPU Program of Central Unit
1 CP544-1ÀÇ
2¹ø 752 ModuleÀº Central Unit
1ÀÇ CPU¿Í PCÀÇ WinCC HMI Program°ú
Åë½ÅÀ» ÇÒ ¼ö ÀÖµµ·Ï
ÇÁ·Î±×·¥À» Çϸç, ÀϹÝÀûÀ¸·Î
¸ð´ÏÅÍ »ó¿¡¼ ÀÔ·ÂÇÏ´Â Parameter
°ª°ú ÀåºñÀÇ ¸ðµç »óȲÀ»
¸ð´ÏÅÍ¿¡¼
ÀåºñÀÇ ¸ðµç »óȲÀ» ¸ð´ÏÅÍ¿¡¼
È®ÀÎÇÒ ¼ö ÀÖµµ·Ï ÇÁ·Î±×·¥ÇÕ´Ï´Ù. -.
CPU Program of Central Unit
2 CP544-2ÀÇ
2¹ø 752 ModuleÀº Central Unit
2ÀÇ CPU¿Í PCÀÇ WinCC HMI Program°ú
Åë½ÅÀ» ÇÒ ¼ö ÀÖµµ·Ï ÇÁ·Î±×·¥À»
Çϸç, ÀϹÝÀûÀ¸·Î ¸ð´ÏÅÍ »ó¿¡¼
ÀÔ·ÂÇÏ´Â Parameter °ª°ú ÀåºñÀÇ
¸ðµç »óȲÀ» ¸ð´ÏÅÍ¿¡¼
ÀåºñÀÇ ¸ðµç »óȲÀ» ¸ð´ÏÅÍ¿¡¼
È®ÀÎÇÒ ¼ö ÀÖµµ·Ï ÇÁ·Î±×·¥ÇÕ´Ï´Ù.
|
|
Hardware
Configuration
|
|
¡á Programmable Controller -
S5-135/155U / CPU928 or CPU948 -.
Communication Processor : CP544 -.
Interface Module : Duel 752
modules (RS422-A / RS485) Connection
CP to CP : Point to Point ¡æ
Path : 752 Module1 of CP1 -
UTP Cable - 752 Module of CP2 Connection
CP to PC : RS422-A(RS485) /
R232C ¡æ
Path : 752 Module2 of CPs -
UTP Cable - IC 485(Convert RS422-A
to RS232C) -
UTP Cable - COMs Port
|
|
¡á
Ndustrila
Ethernet
|
|
|
|
[ CP1430TF-1
]
|
|
|
[
CP1430TF-2 Presetting
]
|
[
Ethernet IP Adress
]
|
|
|
How
to use about CP1430 TF
|
|
¡á Communication Processor :
CP1430 TF
-.
Åë½Å¸ðµâ·Î´Â SIEMENSÀÇ CP1430
¸ðµâÀ» »ç¿ëÇÏ¿© 2´ëÀÇ Central
Units°ú PC°£ÀÇ Åë½ÅÀ» ÇÒ
¼ö ÀÖµµ·Ï Çß½À´Ï´Ù. CP1430
Åë½Å¸ðµâ¿¡´Â SINEC H1 Interface
ModuleÀ» »ç¿ëÇÏ¿© Transceiver¸¦
ÅëÇØ Data°¡ È帣´Â Back-Bone
Cable(Yellow CabloeÀ̶ó°íµµ
ÇÔ)·Î ¿¬°áµÇ¾î PC¿¡ ÀåÂøµÈ CP1613
Network Card·Î
¿¬°áµÇ¾î ÀåºñÀÇ ¿î¿µ»óȲÀ» ¸ð´ÏÅ͸µ
ÇÒ ¼ö ÀÖ½À´Ï´Ù. SINEC
H1 Network SystemÀº ³ôÀº ¾ÈÁ¤¼º°ú
¸Å¿ì ºü¸¥ Åë½Å¼Óµµ(10 Mbit/s)¸¦
ÀÚ¶ûÇÕ´Ï´Ù.
|
|
CP
Programming in CPU
|
|
¡á SEND / RECEIVE (FETCH) Program
: Between CPU1 and CPU2 -.
CPU Program of Central Unit
1 SINEC
H1 Interface ModuleÀº Trasceiver¸¦
ÅëÇØ Data Line¿¡ È帣´Â Data¸¦
Central Unit 2ÀÇ CPU¿Í Åë½ÅÇÒ ¼ö
ÀÖµµ·Ï SEND / RECEIVE JOB ¿µ¿ªÀ»
ÁöÁ¤ÇÑ´Ù. -.
CPU Program of Central Unit
2 SINEC
H1 Interface ModuleÀº Trasceiver¸¦
ÅëÇØ Data Line¿¡ È帣´Â Data¸¦
Central Unit 1ÀÇ CPU¿Í Åë½ÅÇÒ ¼ö
ÀÖµµ·Ï SEND / RECEIVE JOB ¿µ¿ªÀ»
ÁöÁ¤ÇÑ´Ù.
¡á
SEND ALL / RECEIVE ALL Program
: Between CPUs and PC -.
CPU Program of Central Unit
1 & 2 SINEC
H1 Interface ModuleÀ» ÅëÇØ CPU
1ÀÇ ¸ðµç Data¸¦ PCÀÇ WinCC HMI
ProgramÀ¸·Î Àü¼ÛÇÏ°í ¶ÇÇÑ
ÀÛ¾÷ÀÚ°¡ ¸ð´ÏÅÍ »ó¿¡¼ º¯°æÇÑ
Parameter Data¸¦ CPUs¿¡ Àü´ÞÇϱâ
À§ÇØ SEND
ALL / RECEIVE ALL ProgramÀ»
ÁöÁ¤ÇÑ´Ù.
|
|
Hardware
Configuration
|
|
¡á Programmable Controller 1
- S5-135/155U / CPU928 or CPU948 -.
Communication Processor : CP1430
TF -. Interface
Module : SINEC H1 Connection
CP to CP ¡æ
SiNEC HI of CP1 - Special 727-1Cable
- Transceiver - Back Bone Cable -
Special 727-1 Cable - SINEC
H1 of CP2 Connection
CP to PC ¡æ
SiNEC HI of CPs - Special 727-1Cable
- Transceiver - Back Bone Cable -
Special 727-1 Cable - CP1613
Network Card of PC
|
|